Mitsubishi Electric RD62P2E Application User's Manual page 69

High-speed counter module
Table of Contents

Advertisement

CH1 Synchronization latch count value
• The present counter value is latched by synchronizing with the fall of the synchronization signal during the execution of the
synchronization control function (during the inter-module synchronization control).
• In this area, the present counter value is latched only in the pulse count mode.
• The range of the stored value is between -2147483648 and 2147483647 (32-bit signed binary value).
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory address name
CH Synchronization latch count value
CH1 PWM output cycle time setting
• Set the time of one cycle for the PWM output.
• The setting range is between 0 and 2147483647 (in increments of 0.1s).
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory address name
CH PWM output cycle time setting
CH1 PWM output ON time setting 1
• Set the ON time of the PWM output of the PWM output point No.1 terminal (EQU1).
• The setting range is between 0 and 2147483647 (in increments of 0.1s). In addition, set a value that is equal to or smaller
than the setting value in CH PWM output cycle time setting (Un\G256 to Un\G257, Un\G272 to Un\G273) in this area.
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory address name
CH PWM output cycle time setting
CH1 PWM output ON time setting 2
• Set the ON time of the PWM output of the PWM output point No.2 terminal (EQU2).
• The setting range is between 0 and 2147483647 (in increments of 0.1s). In addition, set a value that is equal to or smaller
than the setting value in CH PWM output cycle time setting (Un\G256 to Un\G257, Un\G272 to Un\G273) in this area.
■Buffer memory address
The following shows the buffer memory address of this area.
Buffer memory address name
CH PWM output cycle time setting
CH1 Pulse measurement section setting
Set the pulse measurement section of the pulse measurement function.
Pulse measurement section setting
ON width
OFF width
From the rising edge of the pulse to the rising edge of the next pulse
From the falling edge of the pulse to the falling edge of the next pulse
CH1
30 to 31
CH1
256 to 257
CH1
258 to 259
CH1
260 to 261
Setting value
0
1
2
3
CH2
62 to 63
CH2
272 to 273
CH2
274 to 275
CH2
276 to 277
APPENDICES
Appendix 3 Buffer Memory Areas
A
67