Mitsubishi Electric RD62P2E Application User's Manual page 58

High-speed counter module
Table of Contents

Advertisement

CH1 Counter value smaller (point No.1)
• This signal turns on when the value in CH1 Present value (Un\G2 to Un\G3) is smaller than the one in CH1 Coincidence
output point No.1 setting (Un\G4 to Un\G5).
• This signal turns off when the value in CH1 Present value (Un\G2 to Un\G3) is equal to or larger than the one in CH1
Coincidence output point No.1 setting (Un\G4 to Un\G5).
■Device number
The following table shows the device number of this input signal.
Signal name
CH Counter value smaller (point No.1)
CH1 External preset request detection
• This signal turns on by a preset command from an external input terminal and the on state will be latched.
• This signal turns off by CH1 External preset detection reset command (Y5).
■Device number
The following table shows the device number of this input signal.
Signal name
CH External preset request detection
CH1 Counter value larger (point No.2)
• This signal turns on when the value in CH1 Present value (Un\G2 to Un\G3) is larger than the one in CH1 Coincidence
output point No.2 setting (Un\G6 to Un\G7).
• This signal turns off when the value in CH1 Present value (Un\G2 to Un\G3) is equal to or smaller than the one in CH1
Coincidence output point No.2 setting (Un\G6 to Un\G7).
■Device number
The following table shows the device number of this input signal.
Signal name
CH Counter value larger (point No.2)
CH1 Counter value coincident (point No.2)
• This signal turns on when the value in CH1 Present value (Un\G2 to Un\G3) is equal to the one in CH1 Coincidence output
point No.2 setting (Un\G6 to Un\G7) and the on state will be latched.
• This signal turns off when CH1 Coincidence signal No.2 reset command (Y7) is turned on. Even if the value in CH1 Present
value (Un\G2 to Un\G3) is kept to be equal to the one in CH1 Coincidence output point No.2 setting (Un\G6 to Un\G7), this
signal does not turn on. After once the value in CH1 Present value (Un\G2 to Un\G3) becomes not equal to the one in CH1
Coincidence output point No.2 setting (Un\G6 to Un\G7), this signal turns on when the value in CH1 Present value (Un\G2
to Un\G3) becomes equal to the one in CH1 Coincidence output point No.2 setting (Un\G6 to Un\G7) again.
■Device number
The following table shows the device number of this input signal.
Signal name
CH Counter value coincident (point No.2)
APPENDICES
56
Appendix 2 I/O Signals
CH1
X3
CH1
X4
CH1
X5
CH1
X6
CH2
XA
CH2
XB
CH2
XC