Appendix 5 When Connecting The Module To A Remote Head Module; Restricted Functions And Specifications; Communication Example - Mitsubishi Electric MELSEC iQ-R AnyWireASLINK User Manual

Master module
Table of Contents

Advertisement

Appendix 5
This section describes the restrictions and communication example for when connecting the RJ51AW12AL to a remote head
module.

Restricted functions and specifications

Function
As for the iQSS functions (such as backup/restoration and automatic reading of system configuration), when the
RJ51AW12AL is mounted on the remote head module, only the functions supported by the remote head module are usable.
For details, refer to the following.
 iQ Sensor Solution Reference Manual
Module parameter
As for the iQSS functions (such as backup/restoration and automatic reading of system configuration), when the
RJ51AW12AL is mounted on the remote head module, only the functions supported by the remote head module are usable.
For details, refer to the following.
 iQ Sensor Solution Reference Manual

Communication example

This section describes the communication example for when connecting the RJ51AW12AL to a remote head module.
System configuration
(1)
(1) Master station (network No.1, station No.0)
• Power supply module: R61P
• CPU module: R04CPU
• CC-Link IE Field Network master/local module: RJ71GF11-T2 (start I/O number: 0000H to 001FH)
(2) Intelligent device station (network No.1, station No.1)
• Power supply module: R61P
• Remote head module: RJ72GF15-T2
• AnyWireASLINK master module: RJ51AW12AL (start I/O number: 0000H to 001FH)
• Output slave module (2-point output ASLINKER): Address 0
• Input slave module (2-point input ASLINKER): Address 0
• Terminating unit
• LED
• Sensor switch
When Connecting the Module to a
Remote Head Module
(2)

Appendix 5 When Connecting the Module to a Remote Head Module

A
APPX
123

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r seriesMelsec iq anywireaslink rj51aw12al