Bit Data Double Verification Setting; Error Status Automatic Recovery Setting; Holding/Clearing Output Data Against Error Setting; Holding/Clearing Word Output Data Against Error Setting - Mitsubishi Electric MELSEC iQ-R AnyWireASLINK User Manual

Master module
Table of Contents

Advertisement

Bit data double verification setting

Set the double verification of the bit data of the RJ51AW12AL.
Item
Double verification
setting

Error status automatic recovery setting

Set whether to automatically recover the RJ51AW12AL from the error status.
Item
Error status automatic
recovery mode setting

Holding/clearing output data against error setting

Set the slave module to hold or clear the output data when the RJ51AW12AL detects the following errors.
• CPU module stop error (IORSTL signal detection)
• System error (NMI signal detection)
• CPU module error (ITERR signal detection)
• ASIC access error (library I/F function access error)
Item
Output data hold/clear
setting when error
occurs

Holding/clearing word output data against error setting

Set the word slave module to hold or clear the input data when a disconnection is detected.
Item
"Word input data hold/
clear setting when error
occurs
2 PARAMETER SETTINGS
50
2.2 Basic Setting
Description
Set the bit data double verification mode. ( Page 19 Double
Verification)
Description
Set the error status automatic recovery mode. ( Page 31 Error
Status Automatic Recovery Function)
Description
Set whether to hold or clear the output data when an error occurs.
Description
Set whether to hold or clear the word input data when a
disconnection is detected.
Setting range
• 0: All points, double verification of a bit
• 1: Double verification of the 16bit(word) until the 1st word
• 2: Double verification of the 16bit(word) until the 2nd word
• 3: Double verification of the 16bit(word) until the 3rd word
• 4: Double verification of the 16bit(word) until the 4th word
• 5: Double verification of the 16bit(word) until the 5th word
• 6: Double verification of the 16bit(word) until the 6th word
• 7: Double verification of the 16bit(word) until the 7th word
• 8: Double verification of the 16bit(word) until the 8th word
• 9: Double verification of the 16bit(word) until the 9th word
• 10: Double verification of the 16bit(word) until the 10th word
• 11: Double verification of the 16bit(word) until the 11th word
• 12: Double verification of the 16bit(word) until the 12th word
• 13: Double verification of the 16bit(word) until the 13th word
• 14: Double verification of the 16bit(word) until the 14th word
• 15: Double verification of the 16bit(word) until the 15th word
• 16: All points, double verification of the 16bit(word)
(Default: 0: All points, double verification of a bit)
Setting range
• 0: No error status automatic recovery
• 1: Error status automatic recovery
(Default: 0: No error status automatic recovery)
Setting range
• 0: CLEAR
• 1: HOLD
(Default: 0: CLEAR)
Setting range
• 0: CLEAR
• 1: HOLD
(Default: 0: CLEAR)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r seriesMelsec iq anywireaslink rj51aw12al

Table of Contents