Inspection Of Ecm, Immobilizer Control Module And Its Circuit - Suzuki Ignis Service Manual

Rg413
Table of Contents

Advertisement

8G-20 IMMOBILIZER CONTROL SYSTEM
TERMINAL
G06-1
G06-2
G06-3
G06-4
INSPECTION OF ECM, IMMOBILIZER CON-
TROL MODULE AND ITS CIRCUIT
ECM, Immobilizer Control Module and its circuit can be checked
at ECM wiring couplers and Immobilizer Control Module wiring
coupler by measuring voltage. Described here is only inspection
of Immobilizer Control Module. For inspection of ECM, refer to
"ENGINE & EMISSION CONTROL INPUT/OUTPUT TABLE" in
Section 6E1.
CAUTION:
Immobilizer Control Module cannot be checked by itself.
It is strictly prohibited to connect voltmeter or ohmmeter
to Immobilizer Control Module with coupler disconnected
from it.
Voltage Check
1) Remove Immobilizer Control Module from steering lock
assembly with ignition switch OFF, referring to "REMOVAL"
of "IMMOBILIZER CONTROL MODULE" in this section.
2) Connect Immobilizer Control Module coupler to Immobilizer
Control Module.
3) Check voltage at each terminal of coupler connected.
NOTE:
As each terminal voltage is affected by the battery volt-
age, confirm that it is 11V or more when ignition switch is
ON.
1. Immobilizer Control Module
2. Immobilizer Control Module coupler
3. Body ground
CIRCUIT
Ground
Data link connector
(Serial data terminal)
Ignition signal
Power source
NOMAL VOLTAGE
4 – 5V
10 – 14V
0 – 0.8V
10 – 14V
CONDITION
Ignition switch ON
Ignition switch ON
Ignition switch OFF
Ignition switch ON

Advertisement

Table of Contents
loading

Table of Contents