6 Assigning Parameters to the Control and the PLC Program

6.10 Linear motors (1FN1 and 1FN3 motors)

6.10
Linear motors (1FN1 and 1FN3 motors)
6.10.1

General information about starting up linear motors

Checks in
the de-energized
state
6-152
Recommended reading
For detailed information about linear motors, encoder and power con-
nections and configuring and assembly, please refer to:
References:
/PJLM/ Planning Guide Linear Motors
The following checks must be made:
1. Linear motor in general
– Which linear motor is being used?
– Is the motor listed?
If yes
Type: 1FN_ _ _ _ –_ _ _ _ _–_ _ _ _
If no
Find out the manufacturer's data for the "unlisted" linear
motor and enter
– Is the cooling circuit operational and is the coolant mixture correct? (Rec-
ommended mix: 75% water, 25% Tyfocor).
2. Mechanical components
– Can the axis move freely over the entire traversing range?
– Do the mounting dimensions of the motor and the air gap between the
primary and secondary parts comply with the manufacturer's specifica-
tions?
– Vertical axis:
If the axis has weight compensation, is this functional?
– Brake:
If a brake is fitted, is it being applied and released correctly?
– Traversing range limitation:
Are mechanical limit stops installed on both sides of the travel path and
bolted securely in position?
– Are the moving cables installed properly in a cable trailing device?