03.96
How are the
The signal leads for motor temperature monitoring on 1FN motors are not
installed in the encoder cable, but in the motor power cable. In order to sense
temperature
the winding temperature of the drive, the temperature sensor signal leads must
sensors
be looped into the encoder cable (temperature sensor coupling lead).
evaluated?
–X411
SIMODRIVE
611 D
Drive A
U2 V2 W2 PE
Power cable
1FN
–X411
SIMODRIVE
611 D
Drive A
U2 V2 W2 PE
Power cable
1FN
Fig. 6-34
Evaluation of KTY temperature sensor (black/white) and switch or PTC (yellow/red)
(whether temperature switch or PTC resistor depends on motor type, i.e. 1FN1 or 1FN3)
 Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
6 Assigning Parameters to the Control and the PLC Program
6.10 Linear motors (1FN1 and 1FN3 motors)
Linear scale
Case a)
The temperature is monitored
via the drive.
Temperature sensor
coupling lead
Linear scale
Evaluation
external
Case c)
The temperature is monitored via
an external device only.
Case b)
The temperature is monitored via the drive and
an external device.
S
Temperature sensor via drive
S
External temperature switch on 1FN1
S
On 1FN3 with PTC resistors via
control unit
Linear scale
–X411
SIMODRIVE
611 D
Temperature sensor
coupling lead
Drive A
U2 V2 W2 PE
Power cable
1FN
Evaluation
external