07.98
07.98
05.97
03.96
Display
This number defines the alarm display type:
0: Display in alarm line
1: Display in a dialog box
Help ID
MMC 101/102/103 only (with hard disk): The default "0" means: The WinHelp
file supplied by Siemens provides a detailed description of the alarm. A value
between 1 and 9 uses an assignment entry in the MBDDE.INI file to refer to a
WinHelp file created by the user. See also 8.1.5, HelpContext.
Text or alarm number
The associated text is given in inverted commas with the position parameters.
S
S
S
S
Format of the
The ASCII file for PLC alarm texts is structured as follows:
text file for
PLC alarm texts
Table 8-3
Alarm
no.
510000
600124
600224
600324
703210
...
703211
// Alarm text file for PLC alarms
References:
Display
This number defines the alarm display type:
0: Display in the alarm line
1: Display in a dialog box
Help ID
MMC 101/102/103 only (with hard disk): The default "0" means: The WinHelp
file supplied by Siemens provides a detailed description of the alarm. A value
between 1 and 9 uses an assignment entry in the MBDDE.INI file to refer to a
WinHelp file created by the user. See also 8.1.5, HelpContext.
 Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
The characters " and # must not be used in alarm texts.
The character % is reserved for displaying parameters.
If the user wishes to use an existing text, a reference to the appropriate
alarm text can be inserted. 5-digit alarm number instead of "text".
The alarm text file may contain comment lines which must start with "//". The
maximum length of the alarm text is 110 characters for a 2-line display. If the
text is too long, it is cut off and the symbol "*" added to indicate missing text.
Parameter "%1": Channel number
Parameter "%2": Block number
Structure of text file for PLC alarm texts
Display
Help ID
Text
1
0
"Channel %K FDDIS all"
1
0
"Feed disable axis %A"
1
0
600124
1
0
600224
1
1
"User text"
1
1
"User text%A ..."
/FB/, P3, "Basic PLC Program"
8 Alarm and Message Texts
8.1
Alarm and message texts
Text on MMC
Channel 1 FDDIS all
Feed disable axis 1
Feed disable axis 2
Feed disable axis 3
User text
User text
Axis 1 ...