Siemens SINUMERIK FM-NC Installation And Startup Manual page 39

Hide thumbs Also See for SINUMERIK FM-NC:
Table of Contents

Advertisement

03.96
Note
Cable with 3 MPI connectors (Order No.: 6FX2002–4EA04–IAF0 (IBA0))
S
S
S
Setting the MCP/
interface to
Table 3-1
customer operator
panel
on
on
Assigned inputs/
The following bytes in the PLC CPU are assigned for the MCP or interface to
outputs in the
the customer operator panel:
PLC CPU
S
S
S
The parameters on FB1 (basic program) for the MCP are already set to the de-
fault values for the standard application.
Communication
If communication does not commence after a PLC reset (MCP LEDs flashing),
does not start
the following points should be checked:
S
S
S
 Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
This cable is used for connecting a standard machine consisting of MMC,
MCP and NCK via OPI/MPI.
It must not be used for setting up an m:n installation.
Components must not be connected using internal bus terminators (e.g.
HHU, HPU), because the cable is already fitted with bus terminators.
Settings on DIP switch S3 for standard application
1
2
3
4
5
off
on
off
on
on
off
on
off
on
on
Input bytes 0–7
Output bytes 0–7
Status bytes for error detection, output bytes 8–11, 12–15 (evaluated by
basic program)
Firmware version of MCP/interface to customer operator panel must be
V03_01_01 or higher
Cable and connector wiring
DIP switch S3 (standard application)
3 Settings, MPI / OPI
3.2
Standard configuration
6
7
8
Meaning:
off
off
MCP:
Baud rate: 1.5 Mbaud
Cyclical transmit pattern: 100 ms
Bus address: 6
off
on
Interface to customer operator
panel:
Baud rate: 1.5 Mbaud
Cyclical transmit pattern: 100 ms
Bus address: 6
3
3-39