Configuring the Unit Settings [Configuration]

Configure the settings of the unit in the [Configuration] tab.
When you connect the personal computer to the unit for the first time, click the [REFRESH] button (B) to retrieve the values set on the unit.
A. Setting target selection list box [Master ROP Number]
B. REFRESH button [REFRESH]
C. Setting item [SETTING ITEM]
D. DATA column [DATA]
E. SET button [SET]
Setting Procedure
1. Select the unit (ROP) to be set.
Click ▼ of [Master ROP Number] (A) to display a list of the IP addresses of ROP units that can be set. From the list, select the IP
address of the ROP you want to set.
Any of the units registered on the [ROP List] tab can be selected.
2. Update the [Configuration] tab display.
Click the [REFRESH] button (B) to retrieve the connection information set on the unit to the personal computer and update the
[Configuration] tab display.
3. Configure the unit settings.
[SETTING ITEM] (C) is displayed for setting items of the ROP selected in step 1.
Configure the settings for the required items in the [DATA] column (D).
RECEIVE PORT
PANEL BRIGHTNESS
LCD BRIGHTNESS
BUZZER
The settings above can also be configured on the unit in setup mode.
4. Confirm the settings.
Confirm the settings.When the settings are complete, click the [SET] button (E) to confirm them.
When the [Do you agree to rebooting after data transfer?] message appears, click the [OK] button.
If you click [CANCEL], the settings are not reflected on the unit.

Configuring camera connection settings [Camera List]

On the [Camera List] tab, configure settings for connections between the ROP and the cameras.
When you connect the personal computer to the unit for the first time, first select the ROP to be set in [Master ROP Number] (A) and then
click the [REFRESH] button (J). The values set on the ROP selected in [Master ROP Number] (A) are acquired.
Each of the [C01] to [C19] lines displays a list of the connection setting information for the corresponding camera number.
A
C
B
E
Set the receive port.
Set the brightness of the panel LED display.
Set the brightness of the LCD screen.
Enable or disable the buzzer (beep/call tone).