6.5.3
Displaying and resetting timers
Procedure
The procedure for displaying a timer is as follows:
1. Press the <TRA> button for five seconds to switch to the trace menu.
2. Choose the timer with the
Resetting timers
The <ACK> button is used to reset the selected value. "rES" flashes in the digital display for
5 seconds. The value is then set to 0. If the parameter lock is activated, "noRE" is displayed
and the value is not reset.
It is possible to reset all timers using the following setting in the trace menu:
All the timers except the runtime meter of the device are reset ("LIV-T" timer).
SITRANS DA400 for oscillating positive displacement pumps with protection against explosion
Operating Instructions, 10/2007, A5E00841127-01
"MEnu" and "TRACE" are shown in the middle section of the digital display. "MEnu"
flashes. After these 5 seconds, the appearance of the digital display is as shown below.
Note
Timers for acoustic channels that are configured with "oFF" (possible for parameters P.1
to P.4) are not displayed.
or
buttons.
Operation
6.5 Trace menu
49