Mdf Cable Line Connection On 7360 Isam Fx-12 - Nokia 7360 Intelligent Services Access Manager FX Series Hardware Installation Manual

Ansi
Hide thumbs Also See for 7360 Intelligent Services Access Manager FX Series:
Table of Contents

Advertisement

ANSI Hardware Installation Manual
Procedure 37
Proceed as follows to connect the MDF cables for LINE and POTS to the LT card with integrated
splitter:
1
Figure 89
2
3
4
Issue: 09
MDF cabling procedure for LT cards with integrated splitter
Connect the MDF cable for the LINE to the right-hand CHAMP connector on the LT card with
integrated splitter, as shown in Figure 89.

MDF cable LINE connection on 7360 ISAM FX-12

GFC
LT1
LT2
Alarm
Secure the connector with baillocks.
Route and connect the other end of the MDF cable as per site practices.
Connect the MDF cable for the LINE to the left-hand CHAMP connector on the LT card with
integrated splitter, as shown in Figure 90.
3HH-12893-AAAA-TCZZA
PWR
PWR
ALM
ALM
MAJ
LT3
LT4
LT5
LT6
NTA
NTIO
NTB
LT7
LT8
LT9
LT10
ENERGY HAZARD
ROATING FAN BLADES
KEEP FINGERS AWAY FROM
TOP AND BOTTOM OF FAN TRAY
DRAFT
7360 ISAM FX-12 shelf cabling
LT11
LT12
24947
185