7 Machine Data
7.2
Display machine data for ShopTurn
9678
MD number
Standard value: –
Change becomes effective after: POWER ON
Data type: STRING (80 characters)
Significance:
9679
MD number
Standard value: –
Change becomes effective after: POWER ON
Data type: STRING (80 characters)
Significance:
9680
MD number
Standard value: 8
Change becomes effective after: IMMEDIATELY
Data type: WORD
Significance:
9681
MD number
Standard value: 7
Change becomes effective after: IMMEDIATELY
Data type: WORD
Significance:
9686
MD number
Standard value: 9
Change becomes effective after: IMMEDIATELY
Data type: LONG
Significance:
7-62
$MM_CMM_DIRECT ORY_SOFTKEY_PATH3
Path for drive names in directory management
Min. input limit: –
Protection level: 3/4
This MD is used to stipulate the path for the drive name of the 4th softkey (horizontal bar) in
directory management with hard disk network link. If a blank string is entered in the display
machine data this softkey is not displayed.
$MM_CMM_DIRECT ORY_SOFTKEY_PATH4
Path for drive names in directory management
Min. input limit: –
Protection level: 3/4
This MD is used to stipulate the path for the drive name of the 5th softkey (horizontal bar) in
directory management with hard disk network link. If a blank string is entered in the display
machine data this softkey is not displayed.
$MM_CMM_M_CODE_COOLANT_I
M function coolant I
Min. input limit: 0
Protection level: 3/4
This MD is used to stipulate the M function for coolant I; this is output when the tool is
changed.
$MM_CMM_M_CODE_COOLANT_II
M function coolant II
Min. input limit: 0
Protection level: 3/4
This MD is used to stipulate the M function for coolant II; this is output when the tool is
changed.
$MM_CMM_M_CODE_COOLANT_OFF
M function for coolant OFF
Min. input limit: 0
Protection level: 3/4
This MD is used to stipulate the M function for switching the coolant OFF; this is output
when the tool is changed.
SINUMERIK 840D sl Commissioning Manual CNC: ShopTurn – 11/2006 Edition
Max. input limit: –
Units: –
Valid as of software version
ShopTurn 6.1
Max. input limit: –
Units: –
Valid as of software version
ShopTurn 6.1
Max. input limit: 32767
Units: –
Valid as of software version
ShopTurn 6.2
Max. input limit: 32767
Units: –
Valid as of software version
ShopTurn 6.2
Max. input limit: 32767
Units: –
Valid as of software version
ShopTurn 6.3
© Siemens AG 2006 All Rights Reserved