Braking resistors
7.4 Technical data
Duty cycles for braking resistors with a thermostatic switch
Figure 7-7
T [s]: Period duration of braking duty cycle
A [s]: Load duration
P
[W]: Rated power (continuous power rating) of the braking resistor
N
P
max
4 x P
Table 7- 5
Duty cycles
6SE7018-0ES87-2DC0
Duty cycle P
max
A [s]
3
T [s]
90
The following applies when connecting Braking Modules in parallel:
P
N total
4 x P
P
max total
126
Duty cycles for braking resistors with a thermostatic switch
[W]: Peak power of braking resistor (6 x P
[W] = power permitted every 90 s for 20 s
N
6SE7021-6ES87-2DC0
Duty cycle 4 x
Duty cycle P
P
N
20
3
90
90
= 0.9 x total P
of single devices
N
= 0.9 x sum (4 x P
N total
= total P
of single devices
max
)
N
Duty cycle 4 x P
max
20
90
) of single devices
N
System Manual, (SH2), 04/2015, 6SL3097-4AH10-0BP3
6SE7023-2ES87-2DC0
Duty cycle P
Duty cycle 4 x P
N
max
3
20
90
90
High Frequency Drive
N0