Configuration Instructions - Siemens SINAMICS S120 System Manual

High frequency drive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Braking Modules
6.1 Braking Module Booksize
Table 6- 6
Duty cycles
Short duty cycle
A [s]
0.1
T [s]
11.5
The following applies when connecting Braking Modules in parallel:
P
N total
P
max total
6.1.9

Configuration instructions

DC link capacitance
To operate Braking Modules, a minimum capacitance of 440 µF is required in the DC link for
each Braking Module.
The capacitance of the Braking Module of 110 µF is included in the total capacitance value.
Note
Only the components that are connected to each other via the DC link busbar can be
included in the total capacitance.
DC link cable
In a two-row or distributed drive line-up, the DC links are connected to each other via a DC
link cable. When using a Braking Module in the drive line-up, this cable must not be longer
than 10 m. The DC link cable must be twisted and have a minimum cross-section of at least
10 mm
Parallel connection
The Braking Module Booksize Compact 6SL3400-1AE31-0AAx is recommended for the
parallel connection of Braking Modules.
Parallel connection of the Braking Module 6SL3100-1AE31-0AAx should be avoided as
power distribution between the modules is not guaranteed.
Note
When Braking Modules are connected in parallel, the DC link capacitance specified above
must be available for each Braking Module.
98
6SN1113–1AA00–0DA0
Long duty cycle
0.4
210
= 0.9 x total P
of single devices
N
= total P
of single devices
max
.
2
6SL3100–1BE31–0AAx
Short duty cycle
1
68
System Manual, (SH2), 04/2015, 6SL3097-4AH10-0BP3
Long duty cycle
2
460
High Frequency Drive

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents