ABB COMMANDER 1900 Series Programming Manual page 5

Circular chart recorders
Hide thumbs Also See for COMMANDER 1900 Series:
Table of Contents

Advertisement

OPrtOr
LEVEL
Operator Level
bASIC
CONFIG
Basic Config
Set Up Inputs
Set Up Pen Range
AdVNCd
Section 3.1 Page 4
Section 3.2 Page 8
CONFIG
SEtUP
SEtUP
Advanced Config
PENrNG
INPUt
Set Up Pen Range
Set Up Input (PV)
SELECt
SELECt
____
____
Select Pen
Select Channel
PEN–HI
IntYP
____
____
Input Type (PV)
Pen Range High
LNtYP
PEN–LO
____
____
Pen Range Low
Linearizer Type
IN SrC
rNG–HI
_. _ _
______
In Source
Input Range High
OUt. S rC
rNG–LO
______
_. _ _
Input Range Low
Out Source
UNItS
____
Temperature Units
ENG–HI
____
Engineering High
dEC–Pt
____
Decimal Point
ENG–LO
____
Engineering Low
bSPd
____
Broken Sensor Drive
FdLP-I
_. _ _
Fault Detection Level
PrGFLt
_. _ _
Programmable Filter
Setup Chart
Set Up Alarms
Set Up Relay Output*
Section 3.3 Page 9
Section 3.4 Page 12
Section 3.5 Page14
SEtUP
SEtUP
SEt UP
ALArMS
CHArt
rELAYS
Set Up Alarms
Set Up Chart
Set Up Relay
ACKtYP
CHArt
SELECt
____
____
____
Acknowledge Type
Chart Time
Select Relay
ACKSrC
CH–StP
SOUrCE
______
______
____
Stop Chart Signal
Alarm Ack Source
Relay Source
AUtdrP
SELECt
POLrtY
__
____
___
Select Alarm
Auto Pen Drop
Polarity
tYPE
LIFt. E N
___
____
Alarm Type
Pen Lift Enable
PENLFt
trIP
____
____
Pen Lift/Pen Status
Trip Level
HYSt
____
Hysteresis
t–HYSt
____
Time Hysteresis
Fig. 3.2 Basic Configuration Level
*
Set Up Digital Output
Set Up Analog Output
Digital Inputs
Section 3.6 Page 16
Section 3.7 Page 18
Section 3.8 Page 20
dIGtAL
SEt UP
dIGtAL
OUtPtS
ANALOG
INPUtS
Digital Outputs
Set Up Output
Digital Inputs
SELECt
SELECt
SELECt
____
____
____
Select Output
Select Output
Select Digital I/P
OP–SrC
SOUrCE
POLrtY
____
____
___
Output Source
Output Source
Polarity
POLrtY
rNG–HI
____
____
Polarity
Retrans. Range Hi
rNG–LO
____
Retrans. Range Low
HI–OP
____
Output Range High
LO–OP
____
Output Range Low
*
These pages do not appear on the
non-upgradeable version (1901J)
*
Access Page
Scale Adjust
Section 3.9 Page 21
Section 3.10 Page 23
ACCESS
SCALE
PAGE
AdJUSt
Access Page
Scale Adjust
C– PASS
SELECt
__
____
Configure Password
Select PV/Pen/Filter
rESEt
__
Scale Reset
OFFSEt
____
Offset Adjustment
SPAN
____
Span Adjust
SEtPEN
At100
Cal. Pen At 100%
SEtPEN
At
0
Cal. Pen At 0%
CHECK
__. _
Check Pen Cal.
FILtEr
__ Hrt
Mains Filter

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Commander 1900 series

Table of Contents