ACS355 Minimum required parameter settings for PROFINET

The minimum required parameter settings are based on factory default settings.
Parameter
Description
98.02
COMM PROT
SEL
51.01
FBA A type
51.02
Protocol/Profile
51.04
IP Configuration
51.05 ...
IP address
51.08
51.09
Subnet CDR
51.27
FBA PAR
REFRESH
10.01
EXT1
COMMANDS
11.03
REF1 SELECT
16.04
FAULT RESET
SEL
(11.05)
REF1 MAX

ACS355 More parameters read from drive to PLC (optional)

Parameter
Description
54.03 ...
Actual value or
54.10
parameter of drive
51.27
FBA PAR
REFRESH
Setting
EXT FBA
Ethernet
PNIO ABB Pro (11)
Static (0)
192.xxx.xx.xx or any other
required IP address.
24
REFRESH
COMM
COMM
COMM
[Scale max]
Setting
Comment
GGii
GG = parameter group, ii = parameter index
Example, 0104 = actual current; 0145 = motor temp
REFRESH
Updates fieldbus settings (groups 51 to 55)
Comment
Activates fieldbus module
Fieldbus type
Communication profile ABB drives
-
-
24 For subnet mask 255.255.255.0
Updates fieldbus settings (groups 51 to 55)
Fieldbus interface as a source for start and
stop.
Fieldbus interface as a source for speed
reference
Fieldbus interface as a source for fault
reset
Max speed/frequency scaling value (used
in function block/visualization input
SPEED_REF_MAX). Must be less or equal
to drive parameter max speed/frequency.