Advertisement

6 DEDICATED INSTRUCTIONS

6.5 JP/GP.RECV (for the Main Program)

Set
Internal device
data
Bit
Word
(S)
(D1)
(D2)
[Instruction
[Executing
symbol]
condition]
JP.RECV
GP.RECV
Set data
Set data
Network No. of the local station (1 to 239, 254)
Jn
254: The network designated by the valid module during other station
Start I/O signal of the local station's Ethernet module.
Un
(00 to FE
(S)
Head device of the local station that stores the control data.
(D1)
Head device of the local station that stores the reception.
Local station device that is turned on for one scan by the completion of
(D2)
the instruction.
(D2) + 1 is turned on if the instruction execution completes abnormally.
6 - 19
This instruction reads received data.
Link direct device
File register
Bit
Command
Command
Description
access.
: The higher 2 digits of the 3-digit I/O signal.)
H
The local devices and the file register for each program cannot be used as devices
used in setting data.
POINT
The RECV instruction can be executed only when the local station is a
Q/L/QnACPU.
REMARKS
The number of steps for the RECV instruction is 8.
Applicable device
Intelligent
J \
function module
device U \G
Word
JP.RECV
GP.RECV
MELSEC-Q/L
Constant
Index register Zn
K, H
Jn
(S)
(D1)
(D2)
Un
(S)
(D1)
(D2)
1
Set by(
)
User
Character string
User, system
System
Others
Data type
Binary 16 bits
Device name
Bit
6 - 19