J(P).Znwr - Mitsubishi Electric Melsec Q Series User Manual

Ethernet interface module
Hide thumbs Also See for Melsec Q Series:
Table of Contents

Advertisement

6 DEDICATED INSTRUCTIONS

6.14 J(P).ZNWR

Set
Internal device
data
Bit
Word
n1
(D1)
( )
(S)
n2
(D2)
[Instruction
[Executing
symbol]
condition]
J.ZNWR
JP.ZNWR
1,
2
Setting data
Target station network number
Jn
Designates the network number of the target
station.
Target station number
n1
Designates the station number of the target
station.
6 - 68
This instruction writes data to word devices of other stations (ACPU).
Link direct device
File register
Bit
: Can only use T, C, D, W
Command
Command
Description
Applicable device
Intelligent
J \
function module
device U \G
Word
J.ZNWR
JP.ZNWR
Setting range
1 to 239
1 to 64 (Constant):
The station with the
corresponding station number
81
to 89
:
H
H
All stations having the
designated group number
FF
:
H
All stations having the target
network number
MELSEC-Q/L
Index register
Zn
Jn
n1
(D1)
(S)
Jn
n1
(D1)
(S)
3
Set by (
)
User
(Continued to the next page)
Constant
Others
K, H
n2
(D2)
n2
(D2)
Data type
Binary 16 bits
Character string
6 - 68

Advertisement

Table of Contents
loading

Table of Contents