Table 7-7 Error Messages Of The Createdmp Command - Hitachi HF-BX1000 Instruction Manual

Industrial computer
Table of Contents

Advertisement

<Diagnosis>
When this command finishes normally, the command exits without output in the command prompt
window. When this command is terminated with an error, the following error message is
displayed.
Error: In the current settings, memory dump file won't be
saved.
Error: Free disk space is too low.
Error: Systemcall failed. (%s, %x)
%s: Name of the Windows API function where the error
occurred
%x: Error code from the Windows API
Error: You do not have the privilege to run this command.
Please run this command again on "Administrator: Command
Prompt".

Table 7-7 Error Messages of the createdmp Command

Error message
A memory dump cannot be collected with
the current setting. In the memory dump
settings, select a "Complete memory
dump" option.
The free space on the disk is too low.
Increase the free space on the disk and
retry.
An internal error has occurred.
You do not have administrator privileges.
Log on to the computer by using an
administrator account and run the
command again. If User Account Control
(UAC) is enabled, start the command
prompt with administrator privileges and
run the command.
7-19
7. MAINTENANCE OPERATION
Meaning

Advertisement