Loading and Saving a Configuration
2.4.4

Transfer, Modification and Archiving Configurations

Configurations cannot only be displayed on the devices but can also be copied over the
network as files.
Like that, configuration data can be archived (centrally).
It is possible to edit configurations at a workstation and then transfer them to the devices.
The web interface (refer to "Handling in the Web Interface") gives a comfortable overview.
Files can be uploaded or downloaded via the web browser or via TFTP. TFTP transmissions
can also be started via SNMP (refer to Chapter 2.27, "SNMP Network Management" ).
The command line interface (CLI) has copy commands, to load files from a TFTP or save them
on a TFTP server.
During the execution of the copy command, the IP address of the TFTP server and the
required file names are requested interactively.
If a configuration is copied from a TFTP server to the device the format is checked for
plausibility.
Commands to transfer the configurations
< c o p y t f t p { . . . } >
< c o p y r u n n i n g - c o n f i g { . . . } >
< c o p y { . . . c o n f i g } t f t p >
2.4.5

Default Configuration and Reset of a Device

The default configuration of a device contains configuration commands that allow access
to the broadest set of functions of a system. On shipping all devices have the default
configuration. The default configuration is not identical with an empty configuration.
Device Settings
System IP
Subnet mask
Gateway address
Host name
System VLAN
Ethernet ports
Ethernet speed
Optical ports
Opt. port speed
DSL ports
Properties dsl1
Properties dsl2
Serial interfaces
Baud rate
Telnet
SSH
Table 6:
Parameters of the default configuration
20
Value
10.0.0.2
255.255.255.0
10.0.0.1
switch
none
Admin state up
Auto Negotiation
Admin state up
100 Mbps, Full Duplex Yes
Admin state up
Master, 192 kbps
Slave, auto speed
Operation mode con-
figuration
57600 bps, 8N1
Disabled
Enabled
Implicit default value Explicit command
Yes
Yes
10.0.0.1
Yes
Yes
No
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Functions
No
No
No
No
No
Yes
No
Yes
No
Yes
No
No
No
No
No
No
1KGT151021 V000 1