ABB EDS500 Series Function Manual page 36

Ethernet & dsl switches
Hide thumbs Also See for EDS500 Series:
Table of Contents

Advertisement

Alarms and Alarm Configuration
Alarm
Signal qual-
ity warn
threshold
reached
Signal qual-
ity alarm
threshold
reached
SSH server
not ready
SSH server
not ready
SFP is not
inserted
Internal
switch uplink
down
SHDSL
encapsu-
lation mis-
match
Internal
switch inter-
connect
down
Ethernet
remote fault
Monitor is up Alarm
Monitor is
down
Table 15:
Alarms
36
Stage
Enabled
(as
default
value)
Warning
Yes
Alarm
Yes
Warning
Yes
Alarm
Yes
Information
Yes
Alarm
Yes
Alarm
Yes
Alarm
Yes
Alarm
Yes
No
Alarm
No
Config-
Reason
urable
partners has not set
channel bundling.
Yes
Quality of signal too
low.
Yes
Threshold for signal
quality has been sub-
seeded.
Yes
SSH session cannot
(yet) be established.
Yes
Alarm if no session is
ready for a connec-
tion.
No
Shows that a link has
been activated but no
SFP is plugged in.
No
Internal hardware
error condition.
No
Incompatible SHDSL
settings.
No
Internal hardware
error condition.
Yes
Ethernet alarm; for
optical connections:
only one connected
fibre.
Yes
Monitoring by the
monitor is normal.
Yes
Monitoring by mon-
itor is in the state
"backup".
Functions
Command
<set interface {dsl1
| dsl2} sqthresh-
old {{threshold} |
no} [alarm | warn-
ing]> <set switch
{fo1 | fo2} sqthresh-
old {{threshold} |no}
[alarm | warning]>
<set interface {dsl1
| dsl2} sqthresh-
old {{threshold} |
no} [alarm | warn-
ing]> <set switch
{fo1 | fo2} sqthresh-
old {{threshold} |no}
[alarm | warning]>
<set system ssh [no]
warn-ifnotready>
<set system ssh [no]
alarm-ifnotready>
<set switch {fo1 |
fo2} [no] {alarm-if-
down | alarm-ifre-
mote- fault | alarm-
if-up}>
<set monitor [no]
{alarm-ifdown |
alarm-if-up}>
<set monitor [no]
{alarm-ifdown |
alarm-if-up}>
1KGT151021 V000 1

Hide quick links:

Advertisement

Table of Contents
loading