Ethernet Interfaces - ABB EDS500 Series Function Manual

Ethernet & dsl switches
Hide thumbs Also See for EDS500 Series:
Table of Contents

Advertisement

Functions
Certain alarms are set in such a way that they can occur during system start (or as a reaction
to configuration commands).
A list of possible alarms can be displayed with the command <show alarm enabled>. As
soon as an alarm condition applies to one of these alarms it is activated and adopted by the
system-wide state.
The list of active alarms can be displayed with the command <show alarm active>. The web
interface has also an overview of possible and active alarms.
Commands for alarm configuration
< s h o w a l a r m [ . . . ] >
< s e t s w i t c h { f o . . . } [ n o ] { a l a r m - . . . } >
< s e t s w i t c h { f o . . . } s q - t h r e s h o l d { . . . } >
< s e t s w i t c h { f o . . . } [ n o ] { w a r n - . . . } >
< s e t s y s t e m s s h [ n o ] a l a r m - i f - n o t r e a d y > < s e t s w i t c h { f o . . . }
[ n o ] { a l a r m - . . . } >
< s e t s y s t e m s s h [ n o ] w a r n - i f - n o t r e a d y >
< s e t i n t e r f a c e { d s l . . . } [ n o ] { a l a r m - . . . } > < s e t s y s t e m s s h
[ n o ] a l a r m - i f - n o t r e a d y >
< s e t i n t e r f a c e { d s l . . . } s q - t h r e s h o l d { . . . } >
< s e t s y s t e m o v e r t e m p - w a r n i n g { . . . } >
< s e t m o n i t o r [ n o ] { a l a r m - i f - d o w n | a l a r m - i f - u p } >
2.13

Ethernet Interfaces

The Ethernet ports of the EDS500 devices are IEEE 802.3 compliant interfaces capable of Fast
Ethernet, auto negotiation, auto sense and flow control designed as RJ-45 plugs (8P8C) (see
EDS500 Manual - Part 1: Ethernet interfaces (Port1 - Port4)). They support 100Base-TX and
10Base-T.
The default value for speed is: auto (Nway).
Therefore, usually no special configuration of the Ethernet connection settings is necessary.
Still, the following settings can be configured manually:
• Data rate (auto/10/100 Mbps)
• Duplex (auto/full/half)
• Flow control (auto/on/off)
The default value for the interfaces is: shutdown.
Using the default-config (refer to Chapter 2.4.5, "Default Configuration and Reset of a
Device") grants simple connectivity and sets the interface (Admin State = up) to this value: no
shutdown.
The Admin state of a link can be controlled by the following commands: <set switch {fo1 | fo2}
[no] shutdown>.
The auto MDI-X setting which is active by default, allows to establish Ethernet connections
with normal or twisted pair cables. A command can set the connection type to 'MDI' or limit it
to 'MDIX'.
For a better identification of a connection in a topology each optical interface can have a
description (alias).
1KGT151021 V000 1
Ethernet Interfaces