Alarms And Alarm Configuration - ABB EDS500 Series Function Manual

Ethernet & dsl switches
Hide thumbs Also See for EDS500 Series:
Table of Contents

Advertisement

Functions
2.12

Alarms and Alarm Configuration

EDS500 devices have an alarm concept to communicate certain error conditions with an
alarm relay, LEDs for display or software signalisation. The individual alarms (referring to
interfaces or the system) are summarised in the system-wide alarm state. The alarms have
three levels of severity.
Alarm level
No alarm /
information
Warning
Alarm
Table 14:
Alarm level and signalling
The alarm relais is described in EDS500 Manual - Part 1: Alarm-Relais (X2).
The LED display is described in EDS500 Manual - Part 1: Display Elements.
The alarm table can be displayed via the command line interface (CLI) ant the Web interface.
The alarm table can also be evaluated with SNMP (refer to Chapter 2.27.3, "Vendor Specific
Device MIB" and Chapter 2.27.4, "Trap Server and Traps").
Alarm
Speed mis-
match
Link down
Link up
Overtemper-
ature
System
booting
Duplex mis-
match
Link aggre-
gation mis-
match
Table 15:
Alarms
1KGT151021 V000 1
Description
There are no or only informative
conditions
Pre alarm: there is a noncritical
error
Alarm: there is a critical error
Stage
Enabled
(as
default
value)
Warning
Yes
Alarm
No
Alarm
No
Alarm
Yes
Alarm
Yes
Warning
Yes
Alarm
Yes
Alarm- Relais
System
state
alarm LED
(Alarm)
Normal
Off
Normal
Flashing
Alarm
On
Config-
Reason
urable
Yes
Negotiated data rate
does not match set
data rate.
Yes
Shows that the link is
interrupted.
Yes
Shows that the link is
established.
Yes
The allowed system
temperature has been
exceeded.
No
The system starts
anew.
Yes
Settings for duplex of
the communication
partners do not match
(shared links?)
No
Settings for chan-
nel bundling do not
match as one of the
Alarms and Alarm Configuration
Subsystem Alarm
LED (DSL Alarm,
FO Alarm)
No alarm: off
Information: on
On
On
Command
<set switch {fo1
| fo2} [no] {warn-
duplex-mismatch
| warn-speed-mis-
match}>
<set switch fo1
alarm-ifdown>
<set switch fo1
alarm-if-up>
<set system
overtemp-warning
{40-125}>
<set switch {fo1
| fo2} [no] {warn-
duplex-mismatch
| warn-speed-mis-
match}>