6.7.

Display of Malfunction Analysis-4 [C8]

Category of abnormal stalling is shown.
1. Proceed the procedures of 6.1. Preparation of Secret Mode.
2. Push the buttons of
Any number of the list is shown.
• Sensor does not detect anything. → Whole lead disconnection, connectors come off, sensor faulty.
• Sensor detects abnormal changes. → Partial lead disconnection, sensor faulty.
• When Massage mechanism block starts, Sensors are faulty. → Each Motor rotation sensor is faulty.
* If Position sensors are faulty, Sensors do not detect any changes.
and
till C8 appears, and push the OK button.
Operation mode
Display
Abnormal sensors
0
1
3
4
6
10
11
12
13
14
15
Error
Normal
Up/down sensor does not detect changes
Up/down motor rotation sensor
Width sensor does not detect changes
Massaging motor rotation sensor
Tapping motor rotation
Ottoman sensor does not detect changes
Ottoman sensor detects abnormal changes
Reclining sensor does not detect changes
Reclining sensor detects abnormal changes
Heater sensor error