Table 4-6 Rf Modulator Setup Menu Options - Motorola OM 1000 Installation And Operation Manual

Out-of-band modulator
Table of Contents

Advertisement

4-14
Setup and Operation
Table 4-6 describes the fields and available options:
Table 4-6
RF modulator setup menu options
Key
Field
Options
A
INTFC 6:
MOD
B
FREQ
71.00
.
75.25
.
129.00
C
LEVEL
1
.
35
.
40
D
UP
E
MODE
OPERATE
STANDBY
REV TEST
CON TEST
2T TEST
CW TEST
OM 1000 Installation and Operation Manual
Description
Identifies the port to which this setup menu applies.
Sets the RF output frequency in MHz. Scroll through the list of supported
frequencies from 71.00 through 129.00 MHz.
Sets the RF output signal level. The scale from 1 through 40 corresponds to
an output signal level range from +30 dBmV through +50 dBmV.
Displays the MAIN menu.
Sets RF modulator function. Scroll through the list of supported modes:
OPERATE enables receipt of packets from the multiplexer and
transmission of QPSK-modulated output.
STANDBY disables both receipt of packets from the multiplexer and
transmission of a QPSK-modulated output.
REV TEST enables both receipt of packets from the multiplexer and
transmission of a QPSK-modulated output with reversed I and Q
channels.
CON TEST enables both receipt of packets from the multiplexer and
transmission of a QPSK-modulated output with modified digital filter
coefficients.
2T TEST disables receipt of packets from the multiplexer and enables
transmission of a two-tone test signal.
CW TEST disables receipt of packets from the multiplexer and enables
generation and transmission of a CW carrier.
In general, the test modes are reserved for factory testing; however, some
are useful for troubleshooting specific equipment faults. Refer to Section 5,
"Troubleshooting," for more information on modulator test modes.