Remove and replace assemblies

Verifying successful disk replacement from the ACM

acme-dp4400-ACM:~ # showfru disk
Collecting Data............
________________________________________________________________
| ID| State | Status|
|===============================================================|
| 0 | Online| OK
| 1 | Online| OK
| 2 | Online| OK
| 3 | Online| OK
| 4 | Online| OK
| 5 | Online| OK
| 6 | Online| OK
| 7 | Online| OK
| 8 | Online| OK
| 9 | Online| OK
| 10| Online| OK
| 11| Online| OK
| 12| Online| OK
| 13| Online| OK
| 14| Online| OK
| 15| Online| OK
| 16| Online| OK
| 17| Online| OK
Dell EMC Integrated Data Protection Appliance DP4400 2.4 Service Procedures Guide
24
Figure 10 Installing the front bezel
After a disk is replaced, you can run the FRU command line verification from the ACM
to ensure that the replacement was successful.
Procedure
1. Log in to the ACM command line by using SSH.
Use
for the user, and use the common password for the appliance.
root
2. Type the following command: # showfru disk
FW Version| Capacity| Operation| OpStatus|
|
NS01
| 10.69TB | None
|
NS01
| 10.69TB | None
|
NS01
| 10.69TB | None
|
NS01
| 10.69TB | None
|
NS01
| 10.69TB | None
|
NS01
| 10.69TB | Rebuild
|
NS01
| 10.69TB | None
|
NS01
| 10.69TB | None
|
NS01
| 10.69TB | None
|
NS01
| 10.69TB | None
|
NS01
| 10.69TB | None
|
NS01
| 10.69TB | None
|
NS01
| 10.69TB | None
|
NS01
| 10.69TB | None
|
NS01
| 10.69TB | None
|
NS01
| 10.69TB | None
|
NS01
| 10.69TB | None
|
NS01
| 10.69TB | None
3. Verify the state for all disks is "Online," and that the status for all disks is "OK".