6.4.14 XA Position A/D Register (XAPAR)
Address: 0x0038 Initial value: 0x0000
D15
D14
0
0
R
R
D7
D6
XAA_D7
XAA_D6
R/W
R/W
The XA position A/D register indicates the X position A/D conversion result of point A subject to calibration/
6.4.15 YA Position A/D Register (YAPAR)
Address: 0x003A Initial value: 0x0000
D15
D14
0
0
R
R
D7
D6
YAA_D7
YAA_D6
R/W
R/W
The YA position A/D register indicates the Y position A/D conversion result of point A subject to calibration
D13
D12
0
0
R
R
D5
D4
XAA_D5
XAA_D4
R/W
R/W
D13
D12
0
0
R
R
D5
D4
YAA_D5
YAA_D4
R/W
R/W
D11
D10
XAA_D11
XAA_D10
R/W
R/W
D3
D2
XAA_D3
XAA_D2
R/W
R/W
D11
D10
YAA_D11
YAA_D10
R/W
R/W
D3
D2
YAA_D3
YAA_D2
R/W
R/W
75
D9
D8
XAA_D9
XAA_D8
R/W
R/W
D1
D0
XAA_D1
XAA_D0
R/W
R/W
D9
D8
YAA_D9
YAA_D8
R/W
R/W
D1
D0
YAA_D1
YAA_D0
R/W
R/W