Am/Fm Terminal Adjustment Parameters - Toshiba Adjustable Speed Drive H3 Operation Manual

Variable torque adjustable speed drive
Table of Contents

Advertisement

GROUP:AM/FM TERMINAL ADJUSTMENT PARAMETERS
LIQUID CRYSTAL DISPLAY
FM TERMINAL FUNCTION
SELECTION
FREQUENCY METER
ADJUSTMENT
AM TERMINAL FUNCTION
SELECTION
CURRENT METER
ADJUSTMENT
TOSHIBA
ITEM
PARAMETER
NO.
DESCRIPTION
275
"FM" terminal signal selection
276
"FM" terminal calibration
277
"AM" terminal signal selection
278
"AM" terminal calibration
8 - 27
ADJUSTMENT
RANGE
0: Pre-compensation
ref frequency
1: Post-compensation
output frequency
2: Frequency
referencee
3: Output current
4: DC voltage
5: Output voltage
6: Torque current
7: Excitation current
8: PID feedback
value
9: Motor overload
ratio
10: Inverter overload
ratio
11: DBR overload
ratio
12: Input power
13:Output power
14: Meter calibration
(100% fixed output)
15: Peak output
current
16: Peak input voltage
-
0: Pre-compensation
reference
frequency
1: Post-
compensation
output frequency
2: Frequency setting
value
3: Output current
4: DC voltage
5: Output voltage
6: Torque current
7: Excitation current
8: PID feedback
value
9: Motor overload
ratio
10: Inverter overload
ratio
11: DBR overload
ratio
12: Input power
13: Output power
14: Meter calibration
(100% fixed output)
15: Peak output
current
16: Peak input voltage
-
FACTORY
PAGE
SETTING
NO.
0
9-23
0.0 Hz
9-24
3
9-25
0 %
9-25

Hide quick links: