Product description
Node-related indicators
I
Each server node has a separate operation area marked with the
corresponding number. In the table above, server node 1 is used as an
example
Pos. Label
Indicator
Global
Error
indicator,
see also
5
"iRMC-
related
status
signals" on
page 26
ID
indicator,
see also
"iRMC-
6
ID
related
status
signals" on
page 26
Power-on
7
indicator
24
Status
Description
No critical event detected (non CSS
off
component).
orange
Prefailure event detected (non CSS
on
component).
Non CSS component failure
detected.
Possible causes:
– System is out of the specified
flashing
temperature range
orange
– Defective sensor
– CPU error
– Error detected by server
management software
The server has been highlighted
using ServerView Operations
blue on
Manager, iRMC web interface or the
ID button on the front panel for easy
identification.
The server has been highlighted for
flashing
easy identification using the iRMC
blue
with disabled local VGA output.
off
The server is switched off.
– The server node has been
switched on but Power Cycle
Delay settings delay it from
green on
turning on for a specified time.
– The server node is switched on
and operating normally.
flashing
The BMC firmware is starting up after
green
the server node has been connected
slowly
to the mains.