Purchase List (North America)
Purchase List (North America)
The following materials are not included in the auxiliary material package provided by Huawei. You need to purchase them before installation. The installation operations in this document are for reference only.
Item
Sub-item
(1) IDU indoor power cable
IDU power cable
(2) IDU power cable terminal (connected to a power supply device)
(3) IDU power cable terminal (connected to an IDU)
(4) IDU ground cable
IDU ground cable
(5) IDU ground cable terminal (connected to an IDU)
(6) IDU ground cable terminal (connected to a ground bar)
(7) IF cable connector (connected to an IDU)
(8) IF cable connector (connected to an RFU)
(9) IF jumper
IF cable
(10) IF cable
(11) Ground clip for an IF cable
IF cable fixing clip
Cable tie
(12) RFU/BU ground cable
RFU/BU ground cable
(13) RFU ground cable terminal (connected to an RFU)/BU ground cable terminal (connected to a BU)
(14) RFU ground cable terminal (connected to a ground bar)/BU ground cable terminal (connected to a ground bar)
Ground bar
(6) IDU ground
cable terminal
(connected to a
ground bar)
(2) IDU power cable
terminal (connected to
(4) IDU ground
a power supply device)
cable
(1) IDU indoor
power cable
(5) IDU ground
cable terminal
(connected to an
IDU)
(3) IDU power
cable terminal
(7) IF cable
(connected to an
connector
IDU)
(connected to an
IDU)
4
Remarks
10 AWG electronic power cables, each of which spans over a maximum distance of 3 m (10 ft)
Terminal specifications depend on the power supply device.
OT bare crimp terminal, 10 AWG, M6
You are advised to use 6 AWG electronic power cables.
Dual OT-M6 terminal, stud spacing 15.875 mm (0.625 in.)
Terminal specifications depend on the ground bar.
RF coaxial connector, type TNC connector, 50 ohms, elbow/plug, male, nut installation
Coaxial connector, type N connector, 50 ohms, straight/plug, male, nut installation
If cables with a diameter larger than 7.6 mm (0.3, in.) such as RG-8U or 1/2 inch cables, are used as IF cables, IF jumpers are required to
facilitate cable routing.
-
Ground clips matching IF cables must be used for surge protection.
IF cable fixing clips must match IF cables.
-
You are advised to use 6 AWG electronic power cables, which support a maximum transmission distance of 20 m (65.62 ft).
Single OT-M6 terminal
Terminal specifications depend on the ground bar.
DC Power Supplier
(13) RFU ground
cable terminal
(8) IF cable
(connected to an RFU)
connector
(connected to an
(12) RFU ground
cable
(14) RFU ground cable
terminal (connected to a
ground bar)
(11) Ground clip for
an IF cable
(10) IF cable
(9) IF jumper
4
(13) BU ground cable
terminal (connected to a
BU)
(12) BU ground cable
RFU)
(14) BU ground cable
terminal (connected to a
ground bar)