Chapter 3 Appendix
Error Message
C064
4th SMBus device Error
detected.
C065
5th SMBus device Error
detected.
C066
6th SMBus device Error
detected.
C067
7th SMBus device Error
detected.
C068
8th SMBus device Error
detected.
C101
BMC Memory Test Failed.
C102
BMC Firmware Code Area CRC
check Failed.
C103
BMC core hardware
failure.
C104
BMC IBF or OBF check
failed.
C105
BMC SEL area full.
C10B
BMC operational code
corrupted.
C10C
BMC update firmware
corrupted.
C10D
Internal Use Area of BMC
FRU corrupted.
BMC SDR Repository empty. An error was detected on BMC
C10E
C10F
IPMB signal lines do not
respond.
C110
BMC FRU device failure.
C111
BMC SDR Repository
failure.
C112
BMC SEL device failure.
C113
BMC RAM test error.
C114
BMC Fatal hardware error.
C115
Management controller
not responding
C116
Private I2C bus not
responding.
C117
BMC internal exception
C118
BMC A/D timeout error.
C119
SDR repository corrupt.
C11A
SEL corrupt.
C11B
BMC Mezzanine card is not
found.
C11C
BMC Mezzanine partition
is invalid.
128
Cause
An error was detected on 4th SM
Bus.
An error was detected on 5th SM
Bus.
An error was detected on 6th SM
Bus.
An error was detected on 7th SM
Bus.
An error was detected on 8th SM
Bus.
An error was detected on BMC.
An error was detected while
accessing BMC
There is not enough space to
store the system event log.
Failed to start BMC firmware.
An illegality was detected by
update of BMC firmware.
An illegality was detected in FRU
containing the device
information.
SDR.
Failure of Satellite Management
Controller was detected.
An error was detected in FRU
that contains device information.
Failure was detected in SROM
that stores the SDR.
Device failure was detected in
BMC SEL.
An error was detected in BMC
RAM.
A hardware error was
detected in BMC.
Management controller does not
respond.
Private I2C bus does not
respond.
BMC internal error was detected.
BMC A/D timeout error was
detected.
BMC error or illegal SDR data
was detected.
BMC error or illegal system
event log data was detected.
BMC Mezzanine card is not
installed.
A format error was detected in
BMC Mezzanine card.
Express5800/E120d-1 Maintenance Guide
Solution
Contact your sales representative.
Unplug the power cord, wait for at least 30 seconds,
then restart the server. If the same error is detected
repeatedly, contact your sales representative.
Start up Offline Tools (Chapter 1, 9. Offline Tools) and
delete the event logs.
Unplug the power cord, wait for at least 30 seconds,
then restart the server. If the same error is detected
repeatedly, contact your sales representative.
Update the BMC firmware.
If the same error is detected repeatedly, contact your
sales representative.
Unplug the power cord, wait for at least 30 seconds,
then restart the server. If the same error is detected
repeatedly, contact your sales representative.
Contact your sales representative.