Chapter 2 Convenient Features
(2)
Power Control Configuration submenu
From the Server menu, move the cursor to Power Control Configuration and then press the <Enter> key to
show its submenus.
For details about the options, see the table below.
Option
AC-LINK
Power ON Delay Time Mode
Delay Time
Standby Power Save
Parameter
Stay Off
Specify AC link feature. Specify how the DC power state
[Last State]
should be when the AC power is supplied again after loss of
Power On
power. (See the table below)
[Manually Setting]
Select a method to specify the delay time before powering
on DC power. Available options are: "User-specified value"
Random
or "random value".
This option is selectable when Power On or Last State is
specified in AC-LINK.
[45]-600
Specify the delay time within the range between "xx" and
600 seconds. The minimum configurable time is displayed
when executing Load Setup Defaults.
This menu appears when Manually Setting is specified for
Power ON Delay Time Mode.
[Disabled]
Enable or disable the feature that saves the standby power
Enabled
on standby. If this option is set to Enabled, the AC-LINK
setting is fixed to Power On automatically and cannot be
changed. With AC power off state, management,
monitoring, and power-on of server are disabled on remote
site. Powering on the server is available only by pressing
the POWER switch on the server.
If AC-LINK setting is changed from the remote site with this
option being set, you need to press the POWER switch
twice to power on the server.
Express5800/E120d-1 Maintenance Guide
1. System BIOS
Descriptions
[
]: Factory setting