Mitsubishi Electric AE-200A Instruction Book page 31

Air conditioning control system centralized controller
Hide thumbs Also See for AE-200A:
Table of Contents

Advertisement

Item
Display
Date
target
Controller
Comparison
Target
target
Date
Bar graph
WT07992X02
Specify a date to display the data.
Date range
Data storage period
[Day]
The last 24 months
[Month]
The last 24 months
[Year]
The last 2 years
Select [AE] to display the data for AE-200 for comparison, and select [1], [2], [3], or [4] to
display the data for each AE-50/EW-50 for comparison.
Select an EM block name, block name, group name, or address to display the comparison
data.
Note: The selectable items vary, depending on the item selected in the [Display range] field.
Specify a date to display the comparison data.
Note: The same rule as for the [Date] under the [Display target] section apply.
Select an item to display its data in the bar graph.
Note: The selectable items vary, depending on the items selected in the [Display range] and
[Display target] fields.
Display target
Display item
Target value
Electric Energy
Fan operation time
Indoor unit
Thermo-ON time
Thermo-ON time (Cool)
Thermo-ON time (Heat)
Name of the metering device 1
Name of the metering device 2
MCP
(PI controller)
Name of the metering device 3
Name of the metering device 4
Name of the metering device 1
MCP
Name of the metering device 2
(Built-in Pulse
Name of the metering device 3
Input (PI))
Name of the metering device 4
*1 "Energy Management License Pack" is required. (AE-200E/AE-50E/EW-50E only)
*2 If "Energy Management License Pack" has not been registered, only [Day] is available for selection
as a Date range. To select [Month] or [Year], "Energy Management License Pack" is required.
*3 The electric energy consumed by indoor units will appear in the graph. The values are apportioned
based on the setting for [Indoor unit operation apportioning mode] that has been made on the
[Energy Management] screen.
*4 The indoor unit's cumulative operation time for the selected item will appear in the graph.
• [FAN operation time] is the cumulative duration of time in which the indoor unit is ON.
• [Thermo-ON time] is the cumulative duration of time in which the refrigerant is flowing into the
indoor unit. (Thermo-ON time (Cool): when the Cool mode is selected; Thermo-ON time (Heat):
when the Heat mode is selected; Thermo-ON time: when either mode is selected)
*5 The target values will appear in the graph when the target electric energy values are specified on
the [Target value] screen and when the electricity meter is selected in the [Indoor unit electricity
meter] section on the [Energy Management] screen.
*6 A small amount of electric energy consumption may appear in the graph even when no indoor units
have been operated. This is because the standby electric energy is apportioned, which is normal.
Description
Display items for bar graph
Address
-
*3*6
V
*1
*4
*1
V
*4
V
*1
*4
V
*1
*4
V
*1
V
*2
V
*2
V
*2
*2
V
*2
V
*2
V
*2
V
*2
V
31
Display range
Group
Block
EM block
*1*5
*1*5
-
V
V
V
*1
V
*1
V
*1
V
-
-
V
*1
-
-
V
*1
-
-
V
*1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
V: Item that can be displayed in the graph
*1