How to record (CT-203/KXF-W4010; Deck B only)

The cassette deck incorporates the Dolby HX Pro headroom
extension function and auto-bias function to provide a re-
16
cording w ith superior high-frequency characteristics.
Since this unit is not designed for recording w ith metal
(TYPE
) tapes, do not use metal tapes for recording.
Preparation

Normal recording

1
Select the source to be recorded.
2
Perform auto-bias adjustment. (The bias adjustment is applied to deck B.)
3
Set the recording level.
CT-2050/ KXF-W6010
CT-203/ KXF-W4010
Downloaded from:
http://www.usersmanualguide.com/
1
M ake "Playback (recording) preparation".
(CT-203/ KXF-W4010; Insert a tape in deck
B.)
2
(Load a disc in the CD player.)
AUTO BIAS
1
Play a music source.
2
Enter the record-pause mode.
8
PAUSE
REC/ARM
3
Press the M ODE key and select the "BAL."
mode.
MODE
4
Adjust the recording balance.
REC LEVEL/BAL.
/BIAS
Right sound
Left sound
MIN/L
MAX/R
decreases.
decreases.
5
Press the M ODE key and select the
"LEVEL" mode.
MODE
6
Adjust the recording level.
REC LEVEL/BAL.
/BIAS
Recording
Recording
MIN/L
MAX/R
level
level
decreases.
increases.
7
Stop playing the source.
CT-2050/ KXF-W6010 only
0
: Keys and control used in the operations described on this page.
÷ Select by operating the input selector of the amplifier (optional).
÷ In case of recording a FM broadcast,refer to discription of "How to use
the M PX FILTER key" .
"AUTO BIAS" blinks.
÷ The optimum bias is set in about 40 seconds, after w hich the deck
enters the stop mode.
÷ For a fine adjustment after setting AUTO BIAS , refer to the description
of "Bias level adjustment" . (CT-2050/KXF-W6010 only)
÷ To cancel the auto-bias adjustment operation in the middle, press the
stop ( 7 ) key.
÷ ÷ ÷ ÷ ÷ Recording is possible even w hen the auto-bias setting is omitted.
÷ If the amount of remaining tape is small, the auto-bias adjustment may
be canceled in the middle and tape stopped at that position.
÷ The bias level is canceled w hen the eject ( 0 ) key is pressed.
÷ While pressing the PAUSE ( 8 ) key, press the REC/ ARM ( ¶ ) key.
Each press of the M ODE key changes the setting.
1 "LEVEL" lights up: Recording level setting mode
2 "BAL." lights up: Recording balance setting mode
3 "BIAS" lights up: Recording bias setting mode (Deck B of the
CT-2050/ KXF-W6010 only)
4 "LEVEL","BAL.",and "BIAS"go off: Counter display mode
Left channel level
÷ In counter, adjust the recording balance level so that the left and right
displays are the same. You can also check w ith the Ò and  peak level
indicators.
Each press of the M ODE key changes the setting.
1 "LEVEL" lights up: Recording level setting mode
2 "BAL." lights up: Recording balance setting mode
3 "BIAS" lights up: Recording bias setting mode (Deck B of the
CT-2050/ KXF-W6010 only)
4 "LEVEL","BAL.",and "BIAS"go off: Counter display mode
÷ Adjust the recording level so that the 0 dB of the peak level indicators
sometimes lights up.
÷ The recording level can be adjusted on both decks A and B. (CT-203/
KXF-W4010; Deck B only)
CT-2 0 5 0 / 2 0 3 / KXF-W 6 0 1 0 / W 4 0 1 0 (En/ M )
After approximately
"AUTO BIAS" lightsup.
40 seconds
Right channel level
0dB.
Recording level display.
&
&