Unit Name Setting ([7]Unit Name)
It is possible to assign a unit name.
When searching using Sharp COM Redirection Software, it is possible to verify a communication
destination using the unit name.
Disconnecting All Connections ([D]Disconnect All)
It is possible to disconnect all the TCP/IP connections currently recognized by AN-LS1. Even if the
COM Redirect port is fixed in the Busy status due to a problem, it is possible to force the Ready status
back by carrying out this disconnection.
Entering ADVANCED SETUP MENU ([A]Advanced Setup)
Enters ADVANCED SETUP MENU.
Downloaded from:
http://www.usersmanualguide.com/
setup>7
Unit Name
: AN-LS1
Please Enter
: My An-ls1
(change)
—> My An-ls1
• Unit name can be up to 12 characters.
setup>d
Disconnect All Connections(y/n)?y
Now Disconnecting...
• If Disconnect All is performed while Sharp COM Redirection Software or the Telnet menu is in
use, Sharp COM Redirection Software will be forcibly terminated or the connection via Telnet will
be disconnected.
setup>a
****************** ADVANCED SETUP MENU *********************
[1]Auto Logout Time
[2]COM Redirect Port [3]Busy Reply
[4]Input Hold Time
[5]Network Ping Test
[6]Accept IP Addr(1) [7]Accept IP Addr(2)
[9]Accept All IP Addr [0]Port for Search
[!]Restore Default Setting
[Q]Return to Main Menu
advanced>