Decode Settings
Adjust the Decode Settings when scanning barcodes that are densely packed or
poor quality.
Decode Settings
Setting
Center Decode
Decode Security
Decode Filter
Poor Quality 1D
Reading
Video Mode
EDA71 User Guide
Description
When enabled, the imager scans and decodes a barcode only if
part of the barcode is at the center of the aimer window. This is
useful in situations where several barcodes may be very close
together in the imager field-of-view.
Tap the check box to toggle the feature On or Off.
Select Center Decode to adjust the Window dimensions.
Honeywell recommends leaving the settings at 50 (default) to
define the "center" area for the barcode.
Configurable parameters:
Window top
Window bottom
Window left
Window Right
Use this setting to control the reading tolerance of the decoder.
Lower settings are more lenient when reading low quality
barcodes while higher values are more strict.
Use this setting to modify or reject data strings.
Decode Filter Script
Defines the string of text from the filter script. The script
is included in the DataCollectionService.xml settings file.
Debug Level
Set the filter information level. The default level is 0, no
information. Higher levels emit more information. Level 4
emits the most information.
Enable this setting when scanning damaged or badly printed 1-
D barcodes to improve barcode read success.
Use this setting to specify whether normal or inverse decoding
for linear symbologies is enabled during the execution of
Decode. By default normal video is enabled. Options include:
Normal
Inverse
Normal and Inverse
Default
Disabled
2
None
Disabled
Normal