• For a 1-encoder system, encoder faults are detected using different hardware and
• Stop function category 0 to EN 60204-1:2006 (STO or STOP A to Safety Integrated)
• Safety Integrated functions cannot detect parameterization errors made by the machine
• Motor Modules or the motor must be replaced with a device of the same type, as the
If an internal or external fault occurs, none or only some of the parameterized safety
functions are available during the STOP-F response triggered by the fault. This must be
taken into account when a delay time between STOP F and STOP B is parameterized.
This applies in particular to vertical axes.
Safety Integrated
Function Manual, (FHS), 11/2009, 6SL3097-4AR00-0BP0
WARNING
software monitoring functions. It is not permissible to disable these monitoring functions
and they must be parameterized carefully. Depending on the fault type and responding
monitoring function, stop function category 0 or 1 to EN 60204-1:2006 (fault response
functions STOP A or STOP B to Safety Integrated) is selected.
means that the drives are not decelerate but instead coast to a standstill (the time
required to coast to standstill depends on the kinetic energy). This must be included in
the logic of the protective door lock, for example, by means of logic operation of SSM
(n<nx).
manufacturer. The required safety level can only be reached by by means of an
elaborate acceptance test.
parameter settings will otherwise lead to an incorrect response of the Safety Integrated
functions. The corresponding drive must be re-calibrated after an encoder is replaced.
WARNING
System features
3.2 Safety instructions
45