HUAWEI MC509 Series CDMA LGA Module
Hardware Guide
4.4 Conducted RF Measurement
4.4.1 Test Environment
Test instrument
Power supply
RF cable for testing
4.4.2 Test Standards
Huawei modules meet all 3GPP2 test standards relating to 3G. Each module passes
strict tests at the factory and thus the quality of the modules is guaranteed.
4.5 Conducted Rx Sensitivity and Tx Power
4.5.1 Conducted Receive Sensitivity
The conducted receive sensitivity is a key parameter that indicates the receiver
performance of MC509.
The 3GPP Protocol Claim column in Table 4-2 lists the required minimum values,
and the Test Value column lists the tested values of MC509.
Table 4-2 MC509 conducted Rx sensitivity (Unit: dBm)
Item
CDMA 800
Primary
CDMA1900
Primary
CDMA 800
Diversity
CDMA1900
Issue 02 (2013-05-06)
The compensation for different frequency bands relates to the cable and the test
environment.
The instrument compensation needs to be set according to the actual cable conditions.
1x(FER<0.5%)
EVDO(PER<0.5%)
1x(FER<0.5%)
EVDO(PER<0.5%)
1x(FER<0.5%)
EVDO(PER<0.5%)
1x(FER<0.5%)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Agilent 8960
KEITHLEY 2306
L08-C014-350 of DRAKA COMTEQ or Rosenberger
Cable length: 29cm
3GPP2
Protocol
Claim (dBm)
< –104
< –105.5
< –104
< –105.5
-
-
-
RF Specifications
MC509 Test Value (dBm)
Min.
Typ.
Max.
–107
–104
-
–109
–105.5
-
–107
–104
-
–109
–105.5
-
–106
-
-
–107
-
-
–106.5
-
-
46