IMPORTANT: Make sure all parts are properly
aligned. Do not force center section into position on
the housing.
20.Install center section with valve plates onto transmis-
sion housing (Fig. 72).
Note: When the center section is properly installed,
the cylinder block springs will hold the end center sec-
tion away from the housing about 1/8 inch (3.1 mm).
21.Install six (6) screws that retain the center section to
the housing and torque evenly to 33 to 41 ft.-lb (45 to 56
N-m) (Fig. 73).
22.Rotate pump and motor shafts to make sure trans-
mission is assembled correctly. When properly as-
sembled, a maximum torque of 3.5 ft.-lb (4.7 N-m)
should be required to turn either shaft.
23.Assemble following components as described in the
procedures:
Charge Pump Replacement
In-Line Filter Check Valve Replacement
Filter By-Pass Valve Replacement
Heat Exchanger By-Pass Valve Replacement
Charge Pressure Relief Valve Replacement
Check/High Pressure Relief Valve Replacement
Trunnion Seal Replacement
Shaft Seal Replacement
Hydraulic System (Rev. C)
Page 4 - 62
Figure 72
Figure 73