Siemens SITRANS DA400 Operating Instructions Manual page 57

Process monitoring with protection against explosion
Table of Contents

Advertisement

Construction
Weight (without options)
Dimensions (W x H x D) in mm (inches)
Housing material
Electrical connection via screw-on clamps
Cable inlet via plastic cable joints
Auxiliary power
Rated voltage
Working Area
Current consumption
For connection with approved intrinsically safe circuits with:
We recommend Turck Co. ventilating chips MK72-S13-EXO/24VDC.
Internet address www.turck.com
Certificates and Approvals
Explosion protection according to EN50014, EN50020, EN50021
Intrinsic safety "i"
Labeling
Permissible ambient temperature
SITRANS DA400 with protection against explosion
Operating Instructions, 02/2006, A5E00684661-01
Maximum feed voltage U
Maximum short circuit flux I
Maximum output P
i
Internal capacity C
i
Internal induction L
i
Temperature class T4, T5
Temperature class T6
Approx. 2.5 kg
172 x 320 x 80 (6.8 x 12.6 x 3.2)
Makrolon (Polycarbonate + 20 % glass fibers),
surface attenuated with CrNi layer and painted
DC 16 V
15 to 17 V DC
< 40 mA
≤ 17.4 V
i
≤ 191 mA
i
≤ 1.35 W
≤ 33 nF
≤ 28 µH
TÜV (German Technical Inspectorate) 06 ATEX
2952
II 2(1) G Eel ia [ia] IIC T4/T5/T6
-20° C to +60° C ( -4° F to 140° F)
-20° C to +50° C ( -4° F to 122° C)
9.1 Technical data for the device
Rigid 2.5 mm (0.984'')
Flexible 1.5 mm (0.590'')
Flexible with wire end caps 1.5 mm (0.590'')
1 x Pg 13.5 for 1 cable, ∅ 6 to 12 mm
(0.236 ... 0.472'') (e.g., PROFIBUS)
1 x Pg 13.5 for 3 cables, ∅ 4 mm (0.157")
1 x Pg 11 for 1 cable, ∅ 4 to 10 mm
(0.157 ... 0.394'')
4 x Pg 11 for 2 cables, ∅ 4 mm (0.157") (e.g.,
sensors)
Technical data
9-3