Configure Controls And Switches; Irt8050 - Philips OccuSwitch DALI LRM2070 User Manual

Hide thumbs Also See for OccuSwitch DALI LRM2070:
Table of Contents

Advertisement

4.1

Configure controls and switches

This section describes how to set the infrared group and
channel settings for Infrared remote controls IRT8050 and
IRT9010 .
A
B
ON
C
D
ON
E
F
ON
G
General
ON
ON
1
2 3 4 5 6
7
8
IR Group
Function
Address
1
2
3
Ch1 o /down
Ch2 o /down
ON
Ch3 o /down
ON
Ch4 o /down
ON
Ch5 o /down
ON
ON
ON
All o
ON
ON
All o
All o
All o
Blinds down
Ch1 on/o
Ch2 on/o
Ch3 on/o
Ch4 on/o
Ch5 on/o
All o
All o
All o
All o
All o
All o
Figure 11: IRT8050 settings
4 . 1 . 1

IRT8050

In order to avoid that all lighting circuits in one room
are switched unintentionally, the transmitters present in
one room and their respective receivers can be given a
different infrared group address .
The group address of the transmitter must match the
group address of the OccuSwitch DALI . The group address
of the transmitter can be changed by dipswitches, see
Figure 11 .
IR Group
Address
Function
4
Ch1 on/up
Ch2 on/up
ON
Ch3 on/up
Ch4 on/up
ON
Ch5 on/up
Preset 1
ON
Preset 2
Preset 3
ON
Preset 4
Blinds up
ON
Ch2 on/o
Ch3 on/o
ON
Ch4 on/o
Ch5 on/o
ON
Ch1 on/o
Preset 1/Preset 2
ON
Preset 1/Preset 3
Preset 1/Preset 4
ON
Preset 4/Preset 3
Preset 4/Preset 2
ON
Preset 4/Preset 1
OccuSwitch DALI
User Guide
Page 29
5
6
7
8
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON

Hide quick links: