4Storing Welding Conditions; 5Reproducing Welding Conditions - Panasonic YC-300BZ3YHD Operating Instructions Manual

Dc tig welding power source
Table of Contents

Advertisement

Settings
8.2.4 Storing welding conditions
• Up to 64 welding conditions (P01 to P64) set by custom-
ers can be stored.
Just reproduce your stored welding condition, and you
can proceed with the welding immediately.
<Use the "Welding condition memorandum" (Appendix)
to keep a note of the conditions.>
1
Set "FUNCTION" button to "RECORD."
Note
The screen on the right appears on
the digital ammeter.
2
Turn the JOG dial and select a program number to be stored.
* Numbers starting with "P01" are indicated in order. (Numbers already stored flash.)
<New storage>
• Select a solidly lit (no-flash) number.
• Press the JOG dial, then the "FUNCTION" button automatically returns to "WELD.
<Overwriting>
• Select a number you want to overwrite (the number
flashes)
Note
The screen on the right appears on
.
the digital ammeter.
• Turn the JOG dial and have "YES" displayed.
• Press the JOG dial, then the "FUNCTION" button automatically returns to "WELD."
8.2.5 Reproducing welding conditions
• Welding can be done by reproduction of any desired
condition selected from the stored welding conditions.
• A reproduced welding condition can be changed as
desired. (Once changed, it turns to be different from the
original condition any more.)
1
Set "FUNCTION" button to "PLAY."
Note
The screen on the right appears on
the digital ammeter.
2
Turn the JOG dial and select a program number to be repro-
duced.
* The stored program numbers are indicated in ascending
order. (If there is no program stored, the display is still indi-
cating "P--" when turning the JOG dial.
3
• Press the JOG dial to reproduce.
• To cancel the reproduction or if there is no program to reproduce, set "FUNCTION" button to "WELD".
38
Operation
Operation
Note
When the memory locking is on, no information can be
stored.
Set-value display
(When solidly lit "P02" is
selected.)
(When flashing "P01" is
selected.)
• To store any revised welding condition, use a new pro-
gram number, or store it with the original number by
overwriting unless any inconvenience is caused.
Set-value display
(In case of reproducing
"P01")
LCD display
JOG to Sel. No.
Press to Confirm
Overwrite? (Y/N)
JOG to YES/NO
LCD display
JOG to Sel. No.
Press to Confirm
OMCTT5621E18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents