Table 7 Lubricating Oil Temperature At The Inlet; Table 8 Lubricating Oil Temperature At The Outlet - ABB A145-M56 Operation Manual

Hide thumbs Also See for A145-M56:
Table of Contents

Advertisement

Operation Manual / 4 Product description / A130-M.. - A145-M..
4
Monitoring operation
Lubricating oil temperature at the inlet
Machine damage
If the oil temperature at the oil inlet exceeds the admissible range, this may
lead to engine damage.
CAUTION
Observe oil temperature at the oil inlet according to the following table.
Status for operation
Admissible
Temporarily admissible (< 1 h) → alarm
Not admissible → stop engine
Not admissible → do not start engine (before start: preheat oil)
Table 7: Lubricating oil temperature at the inlet
Lubricating oil temperature at the outlet
The oil temperature at the outlet is mainly dependant on:
 Lubricating oil temperature and pressure at the oil inlet
 Engine load and turbocharger speed
 Exhaust gas temperature
The maximum admissible oil temperature at the outlet is listed in the following table. The spec-
ified oil outlet temperature is to be considered as alarm value for the turbocharger operation
and must be monitored according to the current regulations.
Status for operation
Admissible
Temporarily admissible → alarm
Not admissible → stop engine
Admissible
Temporarily admissible → alarm
Table 8: Lubricating oil temperature at the outlet
If the turbocharger was operated for a longer period of time outside of the admissible range,
ABB Turbo Systems recommends to have the turbocharger inspected by an ABB Turbocharging
Service Station.
© Copyright 2017 ABB. All rights reserved.
Oil temperature at the outlet
HZTL4031_EN
Page 30 / 121
Oil temperature at the inlet
T
oil,inlet
30 ... 105 °C
> 105 °C
> 110 °C
< 30 °C
T
oil,outlet
≤ 160 °C
> 160 °C
> 180 °C
≤ T
+ 55 K
oil,inlet
> T
+ 55 K
oil,inlet
Revision E
January 2017