KX-MB2061CXB/KX-MB2061CX2/KX-MB2062CXB
15.1.3. Frequency and Voltage Adjustment
15.1.3.1. Settings and Connecting
Please connect a Frequency counter to "RFCLK" point on the Digital Board located near the RF unit.
Please connect a Digital multimeter to "+1.8V" point on the Digital Board located near the BBIC.
See the Adjustment Standard (Base Unit) (P.273).
15.1.3.2. Frequency Adjustment
Adjustment value of frequency is the command "SFR".
(default value: 75)
After inputting "EPD_F", please check the RF clock and
input "SFR".
If Frequency displayed on the frequency counter is lower
than 10.368000MHz, please decrease the value. In order to
do it, please write a value with "SFR **" command.
If you decrease 1, input "SFR 74".
If frequency is higher, please write increased value to.
15.1.3.3. Voltage Adjustment
Adjustment value of voltage is the command "VDD".
(default value: 08)
If 1.8V_voltage displayed on the Digital multimeter is higher
than 1.85V, please decrease the value.
Please write a value with "VDD **" command.
If you decrease 1, input "VDD 07".
If voltage is lower, please write increased value to.
Note:
When you write new value to the EEPROM, it is necessary to turn the power off and then power on again.
After power on again, Board works with new value you wrote.