Mitsubishi Electric A800-GF Instruction Manual page 58

Hide thumbs Also See for A800-GF:
Table of Contents

Advertisement

Switches of the FR-A8AP
• Encoder type selection switch (SW3)
Selects either the differential line driver or complementary setting.
It is initially set to the differential line driver. Switch its position according to the
output circuit.
• Terminating resistor selection switch (SW1)
Selects ON/OFF of the internal terminating resistor.
Set the switch to ON (initial status) when an encoder output type is
differential line driver, and set to OFF when complementary.
ON: with internal terminating resistor (initial status)
without internal terminating resistor
OFF:
NOTE
• Set all switches to the same setting (ON/OFF).
• Set the switch "OFF" when sharing an encoder with another unit (NC
(computerized numerical controller), etc.) having a terminating resistor
under the differential line driver setting.
• Prepare an encoder's power supply (5 V/12 V/15 V/24 V) according to the encoder's output voltage. When the control
terminal option FR-A8TP is installed, 24 V power supply can be provided from the FR-A8TP. When the encoder output is the
differential line driver type, only 5 V can be input.
• The SW2 switch is for manufacturer setting. Do not change the setting.
• When the power supply of the inverter is turned OFF, also turn off the power supply of the encoder. Otherwise, the plug-in
option may be damaged.
Encoder specification
Item
Resolution
0 to 4096 Pulse/Rev (setting by Pr. 369)
Power supply voltage
5 V, 12 V, 15 V, 24 V
A, B phases (90° phase shift)
Output signal form
Z phase: 1 pulse/rev
Output circuit
Differential line driver or complementary
Connection of motor with encoder (vector control)
Specification
1
O
2
N
SW2
SW3
Internal terminating
resistor-ON
(initial status)
Internal terminating
resistor-OFF
INSTALLATION AND WIRING
Differential line
driver (initial status)
Complementary
1
O
2
N
SW2
SW3
2
57

Advertisement

Table of Contents
loading

Table of Contents