Connection of motor with encoder (vector control)

2.8
Connection of motor with encoder (vector
control)
Using encoder-equipped motors together with a vector control compatible option enables speed, torque, and positioning
control operations under orientation control, encoder feedback control, and full-scale vector control.
This section explains wiring for use of the FR-A8AP.
Appearance and parts name of FR-A8AP
Terminal layout
Symbol
Name
a
Mounting hole
b
Terminal block
c
Encoder type selection switch (SW3)
d
CON2 connector
Terminating resistor selection switch
e
(SW1)
Switch for manufacturer setting
f
(SW2)
g
Connector
h
LED for manufacturer check
Terminals of the FR-A8AP
Termina
l symbol
PA1
Encoder A-phase signal input terminal
PA2
Encoder A-phase inverse signal input terminal
PB1
Encoder B-phase signal input terminal
PB2
Encoder B-phase inverse signal input terminal
PZ1
Encoder Z-phase signal input terminal
PZ2
Encoder Z-phase inverse signal input terminal
PG
Encoder power supply (positive side) input terminal
SD
Encoder power supply ground terminal
PIN
Not used.
PO
NOTE
• When the encoder's output voltage differs from its input power supply voltage, the signal loss detection (E.ECT) may occur.
• Incorrect wiring or faulty setting to the encoder will cause a fault such as an overcurrent (E.OC[ ]) and an inverter
overload (E.THT).
Correctly perform the encoder wiring and setting.
56
INSTALLATION AND WIRING
(a)
(d)
(f)
PIN and PO
(c)
are not used.
(e)
(a)
Used for installation to the inverter.
Connected with the encoder.
Switches the encoder type (differential line driver/complementary).
Used for extension.
Switches ON or OFF the internal terminating resistor.
Do not change from the initially-set status. (Switches 1 and 2 are OFF
Connected to the option connector of the inverter.
Not used.
Terminal name
Front view
(a)
(h)
1
O
2
N
SW2
SW3
(b)
(a)
Description
A-, B- and Z-phase signals are input from the encoder.
Input terminal for the encoder power supply.
Connect the external power supply (5 V, 12 V, 15 V, 24 V) and the
encoder power cable. When the encoder output is the differential line
driver type, only 5 V can be input. Make the voltage of the external power
supply same as the encoder output voltage. (Check the encoder
specification.)
Rear view
1
O
N
2
Description
(a)
(a)
Refer
to page
59
57
57
.) —
9