List Of Fault Displays - Mitsubishi Electric A800-GF Instruction Manual

Hide thumbs Also See for A800-GF:
Table of Contents

Advertisement

4.4

List of fault displays

For details, refer to the FR-A800 Instruction Manual (Detailed).
Operation panel indication
HOLD
LOCD
to
Er1 to Er4
Er8
to
rE1 to rE8
Err.
OL
oL
TH
PS
SL
CF
CP
SA
to
MT1 to
MT3
UF
HP1
HP2
HP3
LDF
FN
E.OC1
E.OC2
E.OC3
E.OV1
E.OV2
E.OV3
E.THT
E.THM
E.FIN
E.OLT
Name
Operation panel lock
Password locked
Parameter write error
Copy operation error
Error
Stall prevention
(overcurrent)
Stall prevention
(overvoltage)
Electronic thermal relay
function pre-alarm
PU stop
Speed limit indication
(output during speed limit)
Continuous operation
during communication fault
Parameter copy
Safety stop
Maintenance timer 1 to 3
USB host error
Home position return
setting error
Home position return
uncompleted
Home position return
parameter setting error
Load fault warning
Fan alarm
Overcurrent trip during
acceleration
Overcurrent trip during
constant speed
Overcurrent trip during
deceleration or stop
Regenerative overvoltage
trip during acceleration
Regenerative overvoltage
trip during constant speed
Regenerative overvoltage
trip during deceleration or
stop
Inverter overload trip
(electronic thermal relay
function)
Motor overload trip
(electronic thermal relay
function)
Heat sink overheat
Stall prevention stop
Operation panel indication
E. SOT
E.GF
E.LUP
E.LDN
E.LF
E.OHT
E.PTC
E.OPT
to
E.OP1 to
E.OP3
to
E.16 to
E.20
E.PE
E.PUE
E.RET
E.PE2
E.CPU
E. 5 to
to
E. 7
E.CTE
E.P24
E.CDO
E.SER
E.AIE
E.USB
E.SAF
E.PBT
E.13
E.OS
E.OSD
E.ECT
E.OD
to
E.MB1 to
E.MB7
E.EP
E.MP
E.EF
PROTECTIVE FUNCTIONS
List of fault displays
Name
Loss of synchronism
detection
Output side earth (ground)
fault overcurrent
Upper limit fault detection
Lower limit fault detection
Output phase loss
External thermal relay
operation
PTC thermistor operation
Option fault
Communication option fault
User definition error by the
PLC function
Parameter storage device
fault (control circuit board)
PU disconnection
Retry count excess
Parameter storage device
fault (main circuit board)
CPU fault
Operation panel power
supply short circuit/RS-485
terminals power supply
short circuit
24 VDC power fault
Abnormal output current
detection
Communication fault
(inverter)
Analog input fault
USB communication fault
Safety circuit fault
Internal circuit fault
Overspeed occurrence
Speed deviation excess
detection
Signal loss detection
Excessive position fault
Brake sequence fault
Encoder phase fault
Magnetic pole position
unknown
External fault during output
operation
91
4

Advertisement

Table of Contents
loading