SPECIFICATIONS

7.1
Rating
200 V class
Model FR-A820-[ ]-GF
SLD
LD
Applicable motor
capacity (kW)

ND (initial setting)
HD
SLD
Rated
LD
capacity
ND (initial setting)
(kVA)

HD
SLD
LD
Rated current
(A)
ND (initial setting)
HD
SLD
Overload
LD
current rating
ND (initial setting)

HD
Rated voltage

Brake transistor
Regenerative
Maximum brake torque
braking
FR-ABR
(when the option is used)
Rated input
AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
SLD
LD
Without DC
ND
reactor
(initial
setting)
HD
Rated input
current (A)

SLD
LD
ND
With DC reactor
(initial
setting)
HD
SLD
LD
Without DC
ND
reactor
(initial
setting)
Power supply
HD
capacity
SLD
(kVA)

LD
ND
With DC reactor
(initial
setting)
HD
Protective structure (IEC 60529)

Cooling system
Approx. mass (kg)

The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi Electric 4-pole standard motor.

The 0.2 kW motor capacity is applicable under V/F control only.

The rated output capacity indicated assumes that the output voltage is 220 V for 200 V class.

The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for the inverter
and motor to return to or below the temperatures under 100% load.

The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However, the maximum
point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about

Value for the built-in brake resistor

Value for the ND rating

The rated input current indicates a value at a rated output voltage. The impedance at the power supply side (including those of the input reactor and cables) affects the
rated input current.

The power supply capacity is the value when at the rated output current. It varies by the impedance at the power supply side (including those of the input reactor and
cables).

FR-DU08: IP40 (except for the PU connector section)
00046 00077 00105 00167 00250 00340 00490 00630 00770 00930 01250 01540 01870 02330 03160 03800 04750
0.4K
0.75K
1.5K
2.2K
3.7K
0.75
1.5
2.2
3.7
5.5
0.75
1.5
2.2
3.7
5.5
0.4
0.75
1.5
2.2
3.7
0.2
0.4
0.75
1.5
2.2

1.8
2.9
4
6.4
10
1.6
2.7
3.7
5.8
8.8
1.1
1.9
3
4.2
6.7
0.6
1.1
1.9
3
4.2
4.6
7.7
10.5
16.7
25
4.2
7
9.6
15.2
23
3
5
8
11
17.5
1.5
3
5
8
11
110% 60 s, 120% 3 s (inverse-time characteristics) at surrounding air temperature of 40°C
120% 60 s, 150% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
150% 60 s, 200% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
200% 60 s, 250% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
Three-phase 200 to 240 V
Built-in
100% torque/
150% torque/3%ED


3%ED

150% torque/
100% torque/10%ED
10%ED
Three-phase 200 to 240 V 50 Hz/60 Hz
170 to 264 V 50 Hz/60 Hz
±5%
5.3
8.9
13.2
19.7
31.3
5
8.3
12.2
18.3
28.5
3.9
6.3
10.6
14.1
22.6
2.3
3.9
6.3
10.6
14.1
4.6
7.7
10.5
16.7
25
4.2
7
9.6
15.2
23
3
5
8
11
17.5
1.5
3
5
8
11
2
3.4
5
7.5
12
1.9
3.2
4.7
7
11
1.5
2.4
4
5.4
8.6
0.9
1.5
2.4
4
5.4
1.8
2.9
4
6.4
10
1.6
2.7
3.7
5.8
8.8
1.1
1.9
3
4.2
6.7
0.6
1.1
1.9
3
4.2
Enclose type (IP20)
Natural
Forced air
2.0
2.2
3.4
3.4
3.4
5.5K
7.5K
11K
15K
18.5K
22K
7.5
11
15
18.5
22
30
7.5
11
15
18.5
22
30
5.5
7.5
11
15
18.5
22
3.7
5.5
7.5
11
15
18.5
13
19
24
29
35
48
12
17
22
27
32
43
9.1
13
18
23
29
34
6.7
9.1
13
18
23
29
34
49
63
77
93
125
31
45
58
70.5
85
114
24
33
46
61
76
90
17.5
24
33
46
61
76
100% torque/
20% torque/continuous
2%ED

100% torque/6%ED
45.1
62.8
80.6
96.7
115
151
41.6
58.2
74.8
90.9
106
139
33.4
44.2
60.9
80
96.3
113
22.6
33.4
44.2
60.9
80
96.3
34
49
63
77
93
125
31
45
58
70.5
85
114
24
33
46
61
76
90
17.5
24
33
46
61
76
17
24
31
37
44
58
16
22
29
35
41
53
13
17
23
30
37
43
8.6
13
17
23
30
37
13
19
24
29
35
48
12
17
22
27
32
43
9.1
13
18
23
29
34
6.7
9.1
13
18
23
29
6.7
6.7
8.3
15.5
15.5
15.5
.
Rating
30K
37K
45K
55K
75K
90K
37
45
55
75
90/110 132
37
45
55
75
90
110
30
37
45
55
75
90
22
30
37
45
55
75
59
71
89
120
145
181
53
65
81
110
132
165
44
55
67
82
110
132
34
44
55
67
82
110
154
187
233
316
380
475
140
170
212
288
346
432
115
145
175
215
288
346
90
115
145
175
215
288
FR-BU2 (Option)
10% torque/
continuous
185
221
269
178
207
255
150
181
216
266
113
150
181
216
154
187
233
316
380
475
140
170
212
288
346
432
115
145
175
215
288
346
90
115
145
175
215
288
70
84
103
68
79
97
57
69
82
101
43
57
69
82
59
71
89
120
145
181
53
65
81
110
132
165
44
55
67
82
110
132
34
44
55
67
82
110
Open type (IP00)
22
42
42
54
74
74
SPECIFICATIONS
29

Advertisement