Specifications - Mitsubishi Electric 800 Series Instruction Manual

Vector control terminal block
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

5.3

Specifications

Item
±1.5°
Repeated positioning
Depends on the load torque, moment of inertia of the load, orientation, creep speed, or position loop switching
accuracy
position, etc.
Encoder-mounted shaft speed (6000 r/min with 1024 pulse encoder)
Permissible speed
The drive shaft and encoder-mounted shaft must be coupled directly or via a belt without any slip. Gear changing
shafts cannot be applied.
Orientation, creep speed setting, stop position command selection, DC injection brake start position setting,
Functions
creep speed and position loop switch position setting, position shift, orientation in-position, position pulse
monitor, etc.
Holding force after
Under V/F control, Advanced magnetic flux vector control ...... without servo lock function
positioning
Under vector control ...... with servo lock function
Orientation command, forward and reverse rotation commands, stop position command (open collector signal
Input signal
input (complementary) is enabled)
(contact input)
Binary signal of maximum 16 bits (when used with the FR-A8AX)
Output signal
Orientation completion signal, orientation fault signal
(open collector output)
Description
ORIENTATION CONTROL
5
53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a8tp

Table of Contents